PINTEK · 649613251530

Thiết bị đo, phát cao áp để bàn Pintek HVC-801 (40KV DC-GENERATOR)

Sẵn hàngBảo hành: 1 nămXuất xứ: Đài Loan
Liên hệ
Mã sản phẩm
649613251530
Model
HVC-801
Mã nội bộ
PINTEK - HVC-801
Hãng sản xuất
PINTEK
  • HVC-801 is a Electronic Instrument combine High Voltage Probe Calibrator and High Voltage probe meter in one.
  • Provides a small dimension, light weight, and convenient operation.
  • Compliant with CE, GS, UL regulation.
  • HVC-801 keep the max, output currence ~ 0.4mA; and Max. instantaneous short current ~ 15mA to prevent the occurrence of accident.
  • Provides a continuous adjustable output Voltage from 2KV to 40KV. and the loading effect ( for 1000M Ohm, 1/1000 High Voltage Probe ) less than 5%.
  • HVC-801 display by 4 1/2 Red LED easy to observe, High resolution 10V high Accuracy 0.3% make it very suit to use on QC, repairing, RD and education application.
Số lượng
Gọi tư vấn
  • HVC-801 is a Electronic Instrument combine High Voltage Probe Calibrator and High Voltage probe meter in one.
  • Provides a small dimension, light weight, and convenient operation.
  • Compliant with CE, GS, UL regulation.
  • HVC-801 keep the max, output currence ~ 0.4mA; and Max. instantaneous short current ~ 15mA to prevent the occurrence of accident.
  • Provides a continuous adjustable output Voltage from 2KV to 40KV. and the loading effect ( for 1000M Ohm, 1/1000 High Voltage Probe ) less than 5%.
  • HVC-801 display by 4 1/2 Red LED easy to observe, High resolution 10V high Accuracy 0.3% make it very suit to use on QC, repairing, RD and education application.
  • HIGH VOLTAGE PROBE CALIBRATOR
  • Output Voltage:DC + 2KV to + 40 KV adjustable
  • Output Current:<= 0.4mA
  • Accuracy:+/- 0.3% +/- 2 digital
  • Display:4 1/2 digital 0.36" RED LED
  • Resolution:0.01 KV ( 10 V )
  • Power Discharge Time:
  • 1/10 power residual at 4 sec after power off.
  • 1/100 power residual at 8 sec after power off.
  • 1/1000 power residual at 12 sec after power off.
  • HIGH VOLTAGE PROBE METER
  • For:1/1000 high voltage probe only
  • Input Voltage:<= +/- 200V DC ( after attun. )
  • Accuracy:+/- 0.3% +/- 2 digital + H.V. probe accuracy
  • Display:4 1/2 Digital 0.36" RED LED
  • Resolution:0.01 KV ( 10V )
  • POWER SOURCE:115V/230VAC +/-10% ; 50/ 60Hz
  • POWER CONSUMPTION:25W
  • FUSE:
  • Line Voltage Frequency Fuse
  • 110V - 120V 50 / 60 Hz 600 mA
  • 220V - 240V 50 / 60 Hz 300 mA
  • LIMITS OF OPERATION
  • 0 oC ~ + 40 oC
  • 0 ~ 80%? RH
  • STORAGE ENVIRONMENT
  • - 20 oC ~ + 60 oC
  • 0 ~ 90 % RH
  • DIMENSION AND WEIGHT