HT Instruments

HT Instruments · 918951289620

HT Instruments SOLAR IVe I-V curve tracer up to 15A or 1500VDC and PV efficiency logger (15A, 1500VDC)

Sẵn hàngBảo hành: 1 nămXuất xứ: Italy
Liên hệ
Mã sản phẩm
918951289620
Model
SOLAR IVe
Mã nội bộ
HT Instruments - SOLAR IVe
Hãng sản xuất
HT Instruments
  • CERTIFIER OF SINGLE PHASE PV INSTALLATION DC Voltage: 15.0 ÷ 1499.9V; ± (0.5%rdg + 2dgt) AC TRMS Voltage: 50.0 ÷ 265.0 V; ± (0.5%rdg + 2dgt) DC current (by external transducer clamp): -1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV) AC TRMS Current (by external transducer clamp): 1 ÷ 1200; 47.5 ÷ 63.0; ± (0.5%rdg + 0.6mV) 1< FS ≤ 10: 0.05; 0.01 10< FS ≤ 100: 0.5; 0.1 100< FS ≤ 1000: 5A; 1 DC Power (Vmeas > 150V): 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS) 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS) 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS) AC Single phase power (@ PF = 1, Vmeas > 200V): 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS) 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS) 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS) Frequency: 47.5 ÷ 63.0Hz; ±(0.2%rdg+1dgt) Irradiance (by reference cell) : 1 ÷ 65.0; ±(1.0%rdg + 5dgt) Temperature (by external probe PT1000): -20.0 ÷ 100.0; ± (1.0%rdg +1°C)
  • DC Voltage: 15.0 ÷ 1499.9V; ± (0.5%rdg + 2dgt)
  • AC TRMS Voltage: 50.0 ÷ 265.0 V; ± (0.5%rdg + 2dgt)
  • DC current (by external transducer clamp):
  • -1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)
  • AC TRMS Current (by external transducer clamp): 1 ÷ 1200; 47.5 ÷ 63.0; ± (0.5%rdg + 0.6mV)
Số lượng
Gọi tư vấn
  • CERTIFIER OF SINGLE PHASE PV INSTALLATION
    • DC Voltage: 15.0 ÷  1499.9V; ± (0.5%rdg + 2dgt)
    • AC TRMS Voltage: 50.0 ÷ 265.0 V; ± (0.5%rdg + 2dgt)
    • DC current  (by external transducer clamp):
    • -1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)
    • AC TRMS Current (by external transducer clamp): 1 ÷ 1200; 47.5 ÷ 63.0; ± (0.5%rdg + 0.6mV)
    • 1< FS ≤ 10: 0.05; 0.01
    • 10< FS ≤ 100: 0.5; 0.1
    • 100< FS ≤ 1000: 5A; 1
    • DC Power (Vmeas > 150V):
    • 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)
    • 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)
    • 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)
    • AC Single phase power (@ PF = 1, Vmeas > 200V):
    • 1< FS ≤ 10: 0.000k ÷ 9.999k;, 10.00k ÷ 99.99k ±(0.7%rdg + 3dgt)(Imeas < 10%FS)
    • 10< FS ≤ 100:0.000k ÷ 9.999k; 10.00k ÷ 99.99k; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); 100.0k ÷ 999.9k ; ±(0.7%rdg)(Imeas ≥ 10%FS)
    • 100< FS ≤ 1000:0.00k ÷ 99.99k; 100.0k ÷ 999.9k; 1000k ÷ 9999k ; ±(0.7%rdg + 3dgt)(Imeas < 10%FS); ±(0.7%rdg)(Imeas ≥ 10%FS)
    • Frequency: 47.5 ÷ 63.0Hz; ±(0.2%rdg+1dgt)
    • Irradiance (by reference cell) : 1 ÷ 65.0; ±(1.0%rdg + 5dgt)
    • Temperature (by external probe PT1000): -20.0 ÷ 100.0; ± (1.0%rdg +1°C)
  • I-V CURVE and IVCK MEASUREMENTS
    • I-V, IVCK: VDC Voltage @ OPC: 15.0 ÷1499.9; ± (0.5%rdg + 2dgt)
    • I-V, IVCK: IDC Current @ OPC: 0.10 ÷ 15.00; ± (1.0%rdg + 2dgt)
    • I-V: DC Power @ OPC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (1.0%rdg + 6dgt)
    • I-V, IVCK: VDC Voltage (@ STC): 5.0 ÷ 999.9; ± (4.0%rdg + 2dgt)
    • I-V: IDC Current (@ STC): 0.10 ÷ 99.00; ± (4.0%rdg + 2dgt)
    • I-V: DC Power @ STC (Vmpp >30V, Impp >2A): 50 ÷ 99999; ± (5.0%rdg + 1dgt)
    • Irradiance (with reference cell):  1.0 ÷ 100.0; ÷(1.0%rdg+5dgt)
    • Temperature of module (with auxiliary PT1000 probe): -20.0 ÷ 100.0; ÷(1.0%rdg+1°C)